CX2550/60/70 M4 Upgrade and Maintenance Manual 103
Basic software procedures
5.2.20 Resetting the error status after replacing CPUs
5.2.20.1 CPUs
ServerView Operations Manager may report a defective CPU in case of a
critical error.
I Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start > (All) Programs > Fujitsu > ServerView Suite > Agents >
Maintenance Tools
– Windows Server 2012 and above:
Start > Apps > Fujitsu > Maintenance Tools
Ê Choose the CPU status tab.
Ê Select the CPU which shows the pre-failure status.
Ê Click on Reset Status.
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
Ê Log in as root.
Ê Enter the command below, followed by [ENTER]:
– For rack and tower servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
– For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204

Table of Contents

Other manuals for Fujitsu PRIMERGY CX2550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY CX2550 M4 and is the answer not in the manual?

Fujitsu PRIMERGY CX2550 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY CX2550 M4
CategoryServer
LanguageEnglish

Related product manuals