222 Upgrade and Maintenance Manual CX2550/60/70 M4
Processor (CPU)
8.2.8 Concluding steps
Perform the following steps:
Ê "Installing the server node in the server enclosure" on page 67
I If the Global error LED is flashing with error message "CPU has been
changed" on display after the system is powered on, please follow the
procedure below.
Ê Restart the system and wait until the screen output appears.
Ê Press the [F2] function key.
Ê If a password is assigned, enter this password and confirm with the
[Enter] key.
The BIOS setup Main menu will be displayed on the screen.
Ê Select "Commit settings and Exit" on Exit menu.
Ê Confirm LED no flashing.
This information is only regarding to the change of CPU configuration.
There is no technical problem.
Ê "Updating or recovering the system board BIOS and iRMC" on page 77 (if
applicable)
Ê "Enabling replaced components in the BIOS" on page 89
Ê "Controls and indicators on the server node" on page 448
Ê "Enabling replaced components in the BIOS" on page 89
Ê "Resetting the error status after replacing CPUs" on page 103
Ê "Enabling SVOM boot watchdog functionality" on page 88

Table of Contents

Other manuals for Fujitsu PRIMERGY CX2550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY CX2550 M4 and is the answer not in the manual?

Fujitsu PRIMERGY CX2550 M4 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY CX2550 M4
CategoryServer
LanguageEnglish

Related product manuals