EasyManua.ls Logo

Fujitsu PRIMERGY CX2550 M4

Fujitsu PRIMERGY CX2550 M4
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
258 Upgrade and Maintenance Manual CX2550/60/70 M4
Processor (CPU)
8.4.4 Concluding steps
Perform the following steps:
Ê "Installing the server node in the server enclosure" on page 67
I If the Global LED is flashing with error message "CPU has been
changed" on display after the system is powered on, please follow the
procedure below.
Ê Restart the system and wait until the screen output appears.
Ê Press the [F2] function key.
Ê If a password is assigned, enter this password and confirm with the
[Enter] key.
The BIOS setup Main menu will be displayed on the screen.
Ê Select "Commit settings and Exit" on Exit menu.
Ê Confirm LED no flashing.
This information is only regarding to the change of CPU configuration.
There is no technical problem.
"Updating or recovering the system board BIOS and iRMC" on page 77 (if
applicable)
"Controls and indicators on the server node" on page 448
"Resetting the error status after replacing CPUs" on page 103
"Enabling SVOM boot watchdog functionality" on page 88

Table of Contents

Other manuals for Fujitsu PRIMERGY CX2550 M4

Related product manuals