CX2550/60/70 M4 Upgrade and Maintenance Manual 49
Basic hardware procedures
4.1.2.2 Global Error indicator
Ê Check the Global Error indicator on the front panel or I/O panel of the server
(see section "Controls and indicators on the server node" on page 448).
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) see the "Upgrade and Maintenance
Manual" of the related server node.
– Software/agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I For further information, see "ServerView System Monitor" user
guide.
4.1.3 Locating the defective component
After determining the error class by the CSS or Global Error indicators (see
section "Determining the error class" on page 48) local diagnostic indicators on
the system board, HDD modules and PSUs (only slide-in units) allow you to
identify the defective component.
I For further information, see "ServerView Suite Local Service Concept
(LSC)" manual.
4.1.3.1 Local diagnostic indicators on the front
Ê Check the CSS indicator on the front panel of the server enclosure or I/O
panel on the server.
I In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit (see section "Determining the error class" on page 48).