EasyManuals Logo

Honeywell E-Class Series User Manual

Honeywell E-Class Series
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #101 background imageLoading...
Page #101 background image
CS Communicated Speed Commands
This command causes the printer to ignore DPL speed commands. Ignore by setting
value to N. Process by setting value to Y (default). When set to ignore speed values are
controlled via the menu setting.
Parameter: CS
Value / Range: Y, N or 1, 0
Units / Interpretation: Y = Enabled, N = Disabled; or 1 = Enabled, 0 = Disabled
Command Equivalent: N/A
CT Communicated TOF Commands
This command causes the printer to ignore DPL TOF (Gap, Continuous, and
Reflective) commands. Ignore by setting value to N. Process by setting value to Y
(default). When set to DPL TOF values are controlled via the menu setting.
Parameter: CT
Value / Range: Y, N
Units / Interpretation: Y = Enabled, N = Disabled
Command Equivalent: N/A
CU Configuration Upgrade Package Parameters
This command allows an upgrade package to be created.
Parameter CU
Value / Range: See table below.
Units / Interpretation: See table below.
Command Equivalent: N/A
Syntax
<stx>KcCU[nnn1,vvvv1:nnn2,vvvv2:…,nnnn,vvvvn:];
Parameters
Where:
l
nnni,vvvvi: - Configuration Item, Value pairs
l
nnni - Decimal Item Numbers from 1 to 9999
l
, - Decimal Item Number Delimiter
DPL Command Reference
81

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals