UM Units of Measure
See STX m Set Printer to Metric Mode or STX n Set Printer to Imperial Mode for
command details.
Parameter: UM
Value / Range: M, I
Units / Interpretation: M = Metric, I = Imperial
Command Equivalent: <STX>m, <STX>n
UN Plug and Play ID Type
This command controls the type of Plug and Play ID supplied; where Y is for unique
and N for static.
Parameter UN
Value / Range: Y, N
Units / Interpretation: Y = Unique, N = Static
Command Equivalent: N/A
UT User Terminator
This command allows word wrapping of long character strings of commands to the
next line in a file, for the purposes of readability only.
In the <STX>Kc string, the command UTON must fall somewhere before the first line
terminator.
The last command needs to be END, followed by a line terminator (see the EN End
Character command for details).
Parameter UT
Value / Range: ON
Units / Interpretation: N/A
Command Equivalent: N/A
VE Verifier Equipped
This command enables the GPIO for a barcode verifier. See General Purpose Input
Output (GPIO) Port Applications for more information.
Parameter VE
Value / Range: A, D, E, N, Y
Units / Interpretation: See list below.
126