SF Save As Filename
This command, which may be sent separately or included as the last command in an
<STX>Kc command string, saves the effective printer configuration to a file in Flash
memory with a .dcm file extension.
Parameter: SF
Value / Range: Alphanumeric string
Units / Interpretation: Up to 16 characters
Command Equivalent: N/A
SG Sensor Gain Value
This command sets the control of the voltage to the LED emitter of the Media Sensor.
Parameter SG
Value / Range: 0 - 32
Units / Interpretation: N/A
Command Equivalent: N/A
Sl Security Lock
This command provides the ability to password-protect the User Interface.
Parameter SI
Value / Range: N, Y, T
Units / Interpretation: See table below.
Command Equivalent: N/A
Value Security Function
Nxxxx Where xxxx is the current password, this disables Menu protection.
Yxxxx
Where xxxx is a new password, this enables Menu protection and sets
a new password.
Txxxx
Where xxxx is a new password, this enables Menu protection, disables
Test functions, and sets a new password.
Note: To be activated, the default password (0000) must be changed.
SL Stop Location
This command sets the label stopping (and in certain cases the starting) location.
DPL Command Reference
119