l
a - The number of retry attempts, 0-9
l
b - Electronic Article Surveillance (EAS) option: 0 = Set EAS; 1 = Reset EAS; 2 = Test
EAS
l
cc - Two character Manufacturer’s Code, representing one byte
Sample
<STX>KtE9004[CR]
Result
The sample writes the EAS bit for Philips (0x04), retrying nine times if necessary.
STX KtH Read and Feedback Tag Information to Host
Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface
This command returns the tag info to host.
This command only works when the Data Flag for the tag is 0x0F (i.e., when the tag
contains DSFID, AFI, VICC and IC data).
Syntax
<STX>KtH
Sample Feedback
DATA FLAG: 0x0F
TAG ID: E004010000751412
DSFID: 0xE3
AFI: 0x01
NUM BLK: 0x1B
BLK SIZ: 0x03 IC
REF: 0x01
STX KtR Read Data from RFID Tag
Direct Mode – HF [13.56 MHz] ISO15693 Tag Interface
This command instructs the RFID device to read data from the tag and then put that
data into a replaceable field. It is expected that the tag transponder will be within the
read / write distance of the RFID programming device; otherwise, “Void” will be
printed in the text or barcode label field(s).
Syntax
<STX>KtRUn1…n16Haaabbbcdee<CR>
Parameters
Where:
59
DPLCommand Reference