BA Backup After Print
This command determines the timing of the label back up positioning when the
present distance is set and the GPIO option or Present Sensor option (including Peel
and Present) is enabled.
When enabled, the printer immediately backs up the label after the applicator-issued
start of print signal is received or the label is removed, resulting in faster throughput.
If disabled, the printer will not initiate repositioning until the next label is ready to
print (may help prevent the curling of the label edge).
Parameter BA
Value / Range: Y, N
Units / Interpretation: Y = Enabled, N = Disabled
Command Equivalent: N/A
BD Backup Delay
This command sets a time delay for the retraction of a presented label in one-fiftieth
(1/50) of a second increments.
Parameter BD
Value / Range: 0 - 255
Units / Interpretation: 1/50 second
Command Equivalent: N/A
BL Backup Label
This command determines the timing of reverse label motion when the GPIO option is
installed and enabled. See General Purpose Input Output (GPIO) Port Applications for
more information.
Parameter BL
Value / Range: 0, 3, 4
Units / Interpretation: 0 = Disabled, 3 = Active Low, 4 = Active High
Command Equivalent: N/A
BP British Pound
This command, when enabled, will automatically switch from the Number symbol (#)
found at 0x23 (default PC-850 Multilingual Symbol Set) to the British Pound symbol
(£) at 0x9C.
DPL Command Reference
75