Syntax
<STX>Kpmf
Parameters
Where:
l
m - Module ID, Range A to Z (see Memory Module Identifiers and Allocations).
l
f - Flag specifying Enable or Disable protection: 0 = disable protection; 1 = enable
protection
Sample
<STX>KpY0
Result
The sample disables protection for Module Y; graphics may now be downloaded to the
module and, on subsequent resets, these graphics will be protected.
STX Kr Resettable Counter Reset
This command resets the internal counters. Follow this command with an <SOH>U
command to retain the reset or the counters will revert to the previous values after
cycling power.
Syntax
<STX>Kr<CR>
STX KtA Write Application Family Identifier (AFI) to Tag
Direct Mode HF [13.56 MHz] ISO15693 Tag Interface
This command writes the AFI data to the tag.
Syntax
<STX>KtAabcc
Parameters
Where:
l
a - The number of retry attempts, 0-9.
l
b - Lock the Application Family Identifier (AFI) after writing: 0 = No Protection; 1 =
Write Protect
l
cc - Two character AFI value representing one byte.
57