Sample 1
Assume the printer date is set to January 01, 2021.
<STX>L
tD0005
121100001000100 Expiration Date:<STX>D GHI PQ, RSTU
E
Sample 1 prints: Expiration Date: JAN 06, 2021
Sample 2
Assume the printer date is set to January 01, 2021.
<STX>L
tD0005
121100001000100 Expiration Date:<STX>D GHI PQ,
RSTU<STX> <<<<
E
Sample 2 prints: Expiration Date: JAN 06, 2021
STX S Recall Global Data and Place in Field
This command, when in the format record data field, places data from a specified
global register into the data field. See the G Place Data in Global Register command.
Syntax
<STX>Sn
Parameters
Where:
l
n - Specifies the global register (A - P) that contains the data to place into the data
field.
Sample
<STX>L
121100000000000DMX
G
1A2210001000000<STX>SA
E
Result
The sample above places the string "DMX" into the next available global register (A),
and then line 4 is effectively replaced by the data from global register A.