<STX>KD
Parameter
Bit Number
Function Value(s)
z
0 - 1 Reserved Set to 0
2 Reserved Set to 0
3 - 5 Unused Set to 0
6 Always 1 Set to 0
7 Always 0 Set to 0
[1] Selects the values of the control characters. See Control Code Command
Functions for more information.
[2] Ignore Host Distance disregards <STX>O and <STX>f commands (in case host
software sends values that may be inappropriate). Use the <STX>KD command or the
Setup Menu to enable this feature.
Sample
<STX>KD@H@@<CR>
Result
The sample configures 9600 baud, 8-bit words, no parity, with direct thermal printing,
gap sensing, standard control characters, and a cutter.
STX Kd Set File as Factory Default
This command selects the specified file name as the “factory default” configuration.
After execution, subsequent “Select Factory Default” commands will configure the
printer to this file’s configuration using one of the following methods:
l
<STX>KF command.
l
Power-up the printer while pressing the PAUSE and CANCEL Keys.
l
Via the menu SYSTEM SETTINGS / SET FACTORY DEFAULTS entry.
Syntax
<STX>KdName<CR>
Parameters
Where:
l
Name - The name, up to 16 characters, of the file.
l
<CR> - 0x0d terminates the name.
49
DPLCommand Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals