Value / Range: 1 - 255
Units / Interpretation: Specified value multiplied by ten milliseconds.
Command Equivalent: N/A
SA SOP Adjust
This command sets the start of print (SOP) location, relative to the top of form. See
STX O Set Start of Print (SOP) Position for command details.
The EX2 accepts this command for backward compatibility only, limited in range (28-
228).
Parameter SA
Value / Range: 0 255 (128 nominal)
Units / Interpretation: N/A
Command Equivalent: <STX>O
SC Scalable Cache
This command sets the number of 1K blocks allocated for the scalable font engine.
Available memory dependent upon model (see Memory Module Identifiers and
Allocations).
Parameter SC
Value / Range: 100 8192
Units / Interpretation: Kbytes
Command Equivalent: N/A
SE SOP Emulation
This command enables the <STX>O and <STX>f print positioning commands to allow
backward compatibility with label formats designed for other printers.
Parameter SE
Value / Range: A, L, P, D
Units / Interpretation: A = Allegro
L = Prodigy Plus
P = Prodigy
D = Disable
Command Equivalent: N/A
118
DPLCommand Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals