EP End of Print
This command defines the signal output used to signify the End of Print (EOP)
process.
Parameter EP
Value / Range: See table below.
Units / Interpretation: See table below.
Command Equivalent: N/A
Value Units End of Print Interpretation
1 Low Pulse
Outputs a low pulse (approximately 30 milliseconds long) fol-
lowing printing.
2 High Pulse
Outputs a high pulse (approximately 30 milliseconds long)
following printing.
3 Active Low Outputs a logic low (zero) following printing.
4 Active High Outputs a logic high (one) following printing.
EQ Start of Print
This command defines the type of signal input required to control the Start of Print
(SOP) process.
Parameter EQ
Value / Range: See table below.
Units / Interpretation: See table below.
Command Equivalent: N/A
Value Units Start of Print Interpretation
3 Active Low
SOP signal must go low for at least 50 milliseconds to initiate
printing.
4 Active High
SOP signal must go high for at least 50 milliseconds to
initiate printing.
ES ESC Sequences
This command allows data containing invalid ESC control code sequences to be
processed (helpful because some systems send a "banner" to the printer). When set to
"Disabled," ESC sequences are ignored and the data is processed. Bitmapped font
downloads are disabled in this mode.
DPL Command Reference
85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals