<R;C;01;01;0012:0001; Datamax writes RFID best >[CR]
Read ASCII response example:
<R;C;01;01;0013:0001; Datamax writes RFID best >[CR]
Scanner response samples:
A successfully read label:
<S;C;03;03;0002:0001;DATA1;DATA2;DATA3>[CR]
A failed label, successfully retried:
<S;F;02;01;0002:0001;DATA1>[CR]
<S;C;02;02;0002:0001;DATA1;DATA2>[CR]
PC Print Contrast
This command adjusts the relative print edge (gray) component of the print quality,
which allows fine-tuning for specific media/ribbon mix.
Parameter: PC
Value / Range: 0 - 64
Units / Interpretation: N/A
Command Equivalent: N/A
PD Present Distance
This command sets the label stop position past the start of print. When the next label
format is received, the printer will automatically backfeed to the start position. If the
present distance is set to zero, the printer will operate without reversing.
Parameter: PD
Value / Range: 0 400
Units / Interpretation: 1/100 inch
Command Equivalent: <STX>Kf
PE Peel Mode
This command prevents a Feed operation when the label is presented and not
removed.
Parameter: PE
Value / Range: Y, N
Units / Interpretation: Y = Enabled, N = Disabled
Command Equivalent: N/A
DPL Command Reference
109

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals