EasyManuals Logo

Honeywell E-Class Series User Manual

Honeywell E-Class Series
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
l
Variable Length but requires at least three characters.
l
Valid bar widths: The expected ratio of wide to narrow bars can range from 2:1 to
3:1.
l
Valid Codabar symbols require start and stop characters (A–D). These characters
should be placed in the data field along with other data to be included in the sym-
bol.
Sample
<STX>L
D11<CR>
1I63040001501000A1234567890D<CR>
121100000000100Barcode I<CR>
E
Result
Prints a Codabar barcode with a wide to narrow bar ratio of 3:1.
J/j Interleaved 2 of 5 (with a Modulo 10 Checksum) Barcode
Label format barcode ID to print an Interleaved 2 of 5 (with a Modulo 10 Checksum)
with (J) or without (j) human-readable text.
Syntax
J or j
Parameters
Bar Size
Behavior
l
Valid Characters: 0-9
l
Variable Length.
l
Valid bar widths: The expected ratio of wide to narrow bars can range from 2:1 to
3:1.
Sample
<STX>L
D11<CR>
1J000000015010001234567890<CR>
121100000000100Barcode J<CR>
E
DPL Command Reference
193

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals