Syntax
<STX>B
Response
wmmddyyyyhhMMjjj<CR>
Where:
l
w - 1 digit for day of week; 1 = Monday; 7 = Sunday
l
mm - 2 digits for month
l
dd - 2 digits for day
l
yyyy - 4 digits for year
l
hh - 2 digits for hour in 24 hour format
l
MM - 2 digits for minutes
l
jjj - 3 digits for Julian date / constant (see STX A Set Time and Date for details and
restrictions)
Result
1020319960855034<CR>
STX c Set Continuous Paper Length
This command sets the label size for applications to using continuous media. It
disables the top-of-form function performed by the Media Sensor. The sensor,
however, continues to monitor paper-out conditions (see STX M Set Maximum Label
Length).
Syntax
<STX>cnnnn
Parameters
Where:
l
nnnn - Specifies the length of the media feed for each label format, in inches/100
or millimeters/10 (see STX m Set Printer to Metric Mode)
Sample
<STX>c0100
Result
The sample above sets in imperial mode a label length of 100, which equals 1.00 inch.