The example sets the printer to HF, protect after write AFI 11, protect after write
DFSID 22, set EAS Bit (Mfg. Code 0x04), allow 3 tries for each read or write attempt,
lock after writing, erase the tag if there is an error, and use a position of 0.00.
RL Ribbon Low Diameter
This command sets the threshold for a low ribbon indication, where nnnn is the
diameter in hundredths of inches.
Parameter: RL
Value / Range: 100 - 200
Units / Interpretation: 1/100 in.
Command Equivalent: N/A
RM Rewinder Equipped
This command allows the printer to sense the powered internal rewind option.
Parameter RM
Value / Range: A, D, E, N, Y
Units / Interpretation: See list below.
Command Equivalent: N/A
l
A or Y - automatically senses device presence; if undetected, no error is generated.
l
E - enables the device, where its presence must be detected; otherwise, a fault is
generated.
l
N or D - disables device detection.
RO Row Offset
See R Set Row Offset Amount for command details.
Parameter: RO
Value / Range: 0 - 9999
Units / Interpretation: 1/100 in.
Command Equivalent: R
RP Ribbon Low Pause
This command pauses the printer when a Ribbon Low Diameter warning is declared.
The PAUSE Button must be pressed to continue printing.
Parameter RP