Units / Interpretation: 1/100 inch
Command Equivalent: <STX>M
MM Menu Mode
This command sets the menu access level of the printer – where User is a basic listing
of menu settings and controls.
Parameter MM
Value / Range: U, A
Units / Interpretation: U = User, A = Advanced
Command Equivalent: N/A
MT Media Type
This command selects the printing method: Direct Thermal for use with heat sensitive
media or Thermal Transfer for use with media requiring a ribbon to create an image.
Parameter: CL
Value / Range: D, T
Units / Interpretation: D = Direct Thermal, T = Thermal Transfer
Command Equivalent: N/A
MV Mark Value
This command sets threshold value for the reflective media sensor’s “mark”
parameter.
Parameter MV
Value / Range: 0 - 255
Units / Interpretation: N/A
Command Equivalent: N/A
NE Network Configuration
The enhanced configuration two character identifier for the New Network
Configuration Parameters will be ‘NE’ for Network Ethernet.
Parameter NE
Value / Range: See tables below.
Units / Interpretation: See tables below.
Command Equivalent: N/A
96