number specified is exceeded three times, the printer will fault until cleaning is
initiated.
Parameter: HC
Value / Range: 0 - 9999; 0 disables this function
Units / Interpretation: Inches (or centimeters) multiplied by 1000
Command Equivalent: N/A
HE Heat
See Hnn for command details.
Parameter: HE
Value / Range: 0 30
Units / Interpretation: N/A
Command Equivalent: Hnn
HT Host Timeout
This command controls the number of seconds a communications port must be idle
before the printer will process data from a different port or use a different parsing
method. The value is also used to “timeout” an image / label format download (i.e., if,
at any time, data flow stops before a complete label format is received, the data will be
ignored).
Parameter HT
Value / Range: 1 - 60
Units / Interpretation: Seconds
Command Equivalent: N/A
IC Ignore Control Codes
This command allows the user to remove control codes (< 20 Hex) in the data field.
The selected line terminator is processed. When enabled, DPL Control Code (SOH,
STX, CR, ESC, and ^) characters are removed from the data string. (Note that some
fonts do have printable characters in this range and they will not be printed when
enabled.)
Parameter: IC
Value / Range: Y, N or 1, 0
Units / Interpretation: Y = Enabled, N = Disabled; or 1 = Enabled, 0 = Disabled
Command Equivalent: N/A
92
DPLCommand Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals