Value / Range: Alpha character
Units / Interpretation: Model specific ranges (see Speed Ranges).
Command Equivalent: Sa
ST Sensor Type
Sets sensor type.
Parameter: ST
Value / Range: G, C, R
Units / Interpretation: G = Gap (edge), C = Continuous, R = Reflective
Command Equivalent: <STX>e, <STX>r, <STX>c
SV Switch Settings
This command controls recognition of the software switch setting command <STX>V.
Parameter SV
Value / Range: Y, N
Units / Interpretation: Y = Processed, N = Ignored
Command Equivalent: N/A
TP TOF Precedence
This command instructs the firmware to stop printing at the first top of form mark it
detects. The default ("No") prints all of the data (traversing the top of form as
necessary) then slews to the next TOF.
Parameter: TP
Value / Range: Y, N
Units / Interpretation: Y = Enabled, N = Disabled
Command Equivalent: N/A
UD User Label Mode
This command places the printer in standalone operation, which provides menu-
driven processes to print user defined files, including .dlb, .dpl, .prn, and .txt formats.
Parameter UD
Value / Range: Y, N
Units / Interpretation: Y = Enable, N = Disable
Command Equivalent: N/A
DPL Command Reference
125

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals