Syntax
<STX>p
STX Q Clear All Modules
This command instructs the printer to clear all Flash and DRAM modules; see the
printer manual for module options. All stored data will be erased.
Syntax
<STX>Q
STX q Clear Module
This command clears the selected Flash or DRAM module. During normal operations
if a module becomes corrupted (identifiable when the printer responds with a "No
Modules Available" message to a <STX>W command) it must be cleared. All stored
data will be destroyed.
Syntax
<STX>qa
Parameters
Where:
l
a - Memory module designator (see Memory Module Identifiers and Allocations).
STX R Ribbon Saver Control
This command enables the operation of the optional Ribbon Saver. It is the only
command used to control the Ribbon Saver. Its operation is continuous when
enabled. The printer must be set to thermal transfer (ribbon) printing mode then,
during operation, the Ribbon Saver engages automatically, lifting when the minimum
amount of label white space is exceeded.
Syntax
<STX>Rx
Parameters
Where x is:
l
Y - Enabled (Default = Menu selection)
l
N - Disabled
20
DPLCommand Reference