Possible Values Interpretation Transmit Sequence
f - Y/N Y = Printer paused 6
g - Y/N Y = Label presented 7
h - Y/N Y = N (not used) 8
Limitations
For "Interpreter busy (imaging)", Honeywell behavior is not the same as CEE all the
time. Honeywell printers will set it to Y during printing and reset it to N after printing.
SOH a Send ASCII Extended Status String
This command allows the host computer to check an extended current printer status.
The printer returns a string of seventeen characters, followed by a carriage return.
Most characters (see below) indicate an associated condition, either true (Y) or false
(N). Byte 1 is transmitted first. See SOH F Send Status Byte.
Syntax
<SOH>a
Behavior
The printer response is:
l
abcdefgh:ijklmnop:qrstuvwx
Where:
Possible Values Interpretation Transmit Sequence
a - Y/N Y = Interpreter busy 1
b - Y/N Y = Paper out or fault 2
c - Y/N Y = Ribbon out or fault 3
d - Y/N Y = Printing batch 4
e - Y/N Y = Busy printing 5
f - Y/N Y = Printer paused 6
g - Y/N Y = Label presented 7
h - Y/N Y = Rewinder out or fault 8
: : = Always: 9
i - Y/N Y = Cutter Fault 10