STX F Form Feed
This commands the printer to form feed to the next start of print.
Syntax
<STX>F
Behavior
The printer will form feed.
STX f Set Form Stop Position (Backfeed Command)
This command sets the stop position of the printed label, allowing the label to stop at
a point past the start-of-print position. When the next label format is sent, the printer
motor reverses direction to retract the media to the start-of-print position. If
quantities of more than one label are requested, the printer will operate without
backfeeding. Backfeed will then only occur when printing has stopped for a few
seconds.
Syntax
<STX>fnnn
Parameters
Where:
l
nnn - Is a three-digit distance from the Media Sensor, in inches/100 or mm/10.
This distance is independent of the start-of-print position (<STX>O), yet it must be
greater than the start-of-print position to take effect.
Sample
<STX>f230
The sample above sets a stop position distance of 230 (2.3 inches from the media
sensor’s eye).
STX G Print Last Label Format
This command prints a previously formatted label and restarts a canceled batch job
following the last processed label. This is used when there is a label format in the
buffer.
Syntax
<STX>G