l
xx - Symbol set selection.
Sample
<STX>L
ySSW<CR>
Result
The sample selects the Swedish symbol set for use in format records using scalable
fonts.
z Zero (Ø) Conversion to "0"
This command removes the slash zero in fonts 0 to 8, and in the human-readable
field (if any) of the barcodes A to Z. The command applies only to format records
containing those fonts and barcodes, and is effective only for the label format in
which it appears.
Syntax
z
Sample
<STX>L
z
121100000000000Test0000
E
Result
None of the smooth fonts (i.e., Font 9) use the slash zero convention, and this
command will have no effect on scalable fonts.
+ | > | ( Make Last Field entered an Increment Field
This command is used to print sequenced labels. It causes the printer to
automatically increment a field in a batch of labels. The numeric data in the field will
increment by the value assigned after the plus sign (+) each time a label is produced
[or the greater than symbol [>] can be substituted to make the field increment
alphabetically, or the left parenthesis [(] can be substituted to make the field
increment hexadecimal data (valid hexadecimal data is 0-9 or A-F, usually in pairs)].
This command is effective only on the label format record that it follows, and is
intended to be used with the Q, <STX>E, or <STX>G commands.
Syntax
*pii
147
DPLCommand Reference