EasyManua.ls Logo

Honeywell E-Class Series - STX Kb Backfeed Time Delay; STX KC Get Configuration

Honeywell E-Class Series
327 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
l
c - Command 1. Reserved. Should be 0.
l
d - Command 2. Reserved. Should be 0.
l
ee…e - Data to be encoded on RFID tag (HF the last used block will be null-pad-
ded, if necessary). UHF ASCII formats must be 8 or 12 characters; and, UHF Hexa-
decimal formats must be 16 or 24 character pairs.
Sample
<STX>KaW0000054455354[CR]
Result
The sample above writes the data “TEST” at block zero.
STX Kb Backfeed Time Delay
This command controls the time a printed label is allowed to remain “presented”
before being retracted to the start of print position.
Syntax
<STX>Kbnnn<CR>
Parameters
Where:
l
nnn - Seconds/10 (0 to 255)
STX KC Get Configuration
This command returns the configuration of the printer. The form of the returned data
is similar to that of a printed Configuration Label. This command should be parsed by
KEYWORDS, not character positions. Each line is terminated by a CR (0x0d) & LF
(0x0a).
Syntax
<STX>KC<CR>
Behavior
Responds with Printer Configuration and DPL configuration information.
Note: The format of the displayed information will vary with printer, model, firmware version,
and equipped options.
DPL Command Reference
36

Table of Contents

Related product manuals