<STX>L
T00
191100200000000TEST<NULL>
141100001000100TERMINATOR
Q0001
E
Result
The sample above sets a NULL terminator (ASCII NULL: HEX 00) for the data line
termination code. The terminator is immediately restored to a carriage return <CR>, as
seen in the format record containing the text "TERMINATOR".
t Add or subtract date time from the printer date
This command allows the user to print an adjusted date of the printer. This date can
be printed using the Special Label Formatting Command <STX>D. This command
does not change the printer date.
Syntax
txnnnn<CR>
Parameters
Where x is:
l
D - adjust by days
l
W - adjust by weeks
l
M - adjust by months
l
Y - adjust by years
Where:
l
nnnn - 4 digits to be added or subtracted. An optional ‘-‘ may precede the digits to
indicate subtraction.
Sample 1
Assume the printer date is set to January 01, 2021.
<STX>L
tD0005
121100001000100 Expiration Date:<STX>D GHI PQ, RSTU
E
Sample 1 prints: Expiration Date: JAN 06, 2021
DPL Command Reference
144

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals