The sample programs the data “TEST” to the tag with UID “E00700ABCDEF1234” at
block zero then write-protects block zero (attempting to write five additional times if
necessary). When write protecting (locking) with UID, the separate lock command will
also use the addressed mode and the supplied UID.
Note: When using addressed commands and the tag with the specified UID cannot be
found, a standard RFID read/write fault will be issued.
STX KuB Read Data from Gen2 Tag Section
This command reads a specific block address of a Gen2 tag.
Syntax
<STX>KuBaaabbb
Parameters
Where:
l
aaa - Block address number, where: 000 is kill/access section; 001 is EPC section;
002 is Tag ID; and, 003 is user memory.
l
bbb - Data offset in word length.
Sample
<STX>KuB001002
Result
The sample reads the block address 1 at offset word 2, which is location of the EPC
data.
STX KuF Send RFID Device Firmware Version
This command instructs the RFID device to return the firmware version.
Syntax
<STX>KuF<CR>
Printer Response
DEVICE VERSION: XXX.XXX.XXX[CR]
STX KuJ Write Data to Gen 2 Tag Section
This command writes a specific block address of a Gen2 tag.
Syntax
<STX>KuJaaabbb<data>
DPL Command Reference
62

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals