Limitations
This command must be reset to zero for edge or reflective sensing operation.
STX E Set Quantity for Stored Label
This command sets the number of labels for printing using the format currently in the
print buffer. (The printer automatically stores the most recent format received in the
buffer until the printer is reset or power is removed.) When used in conjunction with
the <STX>G command, this will print the format.
Syntax
<STX>Ennnnn<CR>
Parameters
Where:
l
nnnnn - A five-digit quantity, including leading zeros.
l
<CR> - 0x0d terminates the name.
Sample
<STX>E00025
<STX>G
Result
Printer response: 25 labels of the current format in memory will be printed.
Limitations
l
If no <CR> terminates the command, a four-digit quantity (nnnn) can be entered;
and, specifying 9999 will cause continuous printing.
STX e Select Edge Sensor
This command enables the transmissive (see-through) sensing for top-of-form
detection of die-cut and holed (notched) media. This sensor will detect a minimum
gap of 0.1 inches (2.5 mm) between labels. This is the default setting.
Syntax
<STX>e
Limitations
This command is ignored when <STX>cnnnn is issued with a non-zero value for nnnn.
DPL Command Reference
13

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals