Sample
<STX>KtA91C3[CR]
Result
The sample writes 0xC3 AFI byte, locking value, retrying nine times if necessary.
STX KtD Write Data Storage Format Identifier (DSFID) to Tag
Direct Mode HF [13.56 MHz] ISO15693 Tag Interface
This command writes the DSFID data to the tag.
Syntax
<STX>KtDabcc
Parameters
Where:
l
a - The number of retry attempts, 0-9
l
b - Lock the Data Storage Format Identifier (DSFID) after writing: 0 = No Protection;
1 = Write Protect
l
cc - Two character DFSID value representing one byte
Sample
<STX>KtD91C3[CR]
Result
The sample writes 0xC3 DSFID byte, locking value, retrying nine times if necessary.
STX KtE Write Electronic Article Surveillance (EAS) Bit
Direct Mode HF [13.56 MHz] ISO15693 Tag Interface
This command writes the EAS bit for Philips ISO tags.
Syntax
<STX>KtEabcc
Parameters
Where:
DPL Command Reference