EasyManua.ls Logo

Honeywell E-Class Series - VB Application Interfacing Via Windows Driver

Honeywell E-Class Series
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
‘Print label by clicking print button with the mouse
Private Sub cmdPrint_Click()
‘Concatenate all the dynamic data fields with the constant header
strings, terminated with <cr> Chr$(13)
OrderData = OrderTxt & txtOrderNo.Text & Chr$(13) & OrderBC & txtOrderNo.Text &
Chr$(13) & CustomerTxt & txtCustomer.Text
Item1 = Item1NO & txtItem1.Text & Chr$(13) & Item1BC & txtItem1.Text & Chr$(13) &
Item1Txt & txtItem1Desc.Text & Chr$(13) & Item1Qty & txtItem1Qty.Text
‘Concatinate entire label format and send out serial port
PrintLabel = CharSet & MaxLength & Chr$(13) & CharSet & StartLabel & Chr$(13) &
PrintDensity & Chr$(13) & Image1 & Chr$(13) & OrderData & Chr$(13) & Item1 & Chr$(13)
& Fixed & Chr$(13) & EndLabel
Comm1.Output = PrintLabel End Sub
‘Display the record form on the screen
Private Sub Form_Load()
Fixed = Itm1 & Chr$(13) & Chr$(13) & Qty1 & Chr$(13) & Chr$(13) & BoxPos1 & Box-
size & Chr$(13)
CharSet = Chr$(126) ‘Alternate <stx> character ~
MComm.PortOpen = 1 ‘Open the serial port
End Sub
‘Exit the program by clicking Exit button with the mouse
Private Sub cmdExit_Click()
Comm1.PortOpen = 0 ‘Close down the serial port
End
End Sub
VB Application interfacing via Windows Driver
Create a form similar to the following image.
VERSION 5.00
Begin VB.Form Form1
Caption = “Datamax Test Print”
288
DPLCommand Reference

Table of Contents