Parameter
Name
Parameter Value / Range Units / Interpretation
Command
Equivalent
Unit of
Measure
UM M, I
M = Metric,
I = Imperial
<STX>m,
<STX>n
User Label
Mode
UD Y, N
Y = Enabled,
N = Disabled
N/A
User
Terminator
UT ON N/A N/A
Verifier
Equipped
VE A, D, E, N, Y See VE command details. N/A
STX KD Database Configuration
This command, stored in Flash memory for future power-ups, controls the printer’s
environment and operates as a pseudo DIP switch. The <STX>Kc command is
recommended for use over <STX>KD.
Syntax
<STX>KDwxyz<CR>
Parameters
Where w, x, y, and z are binary values with respective bit settings as defined in the
following table. (Bit 0 is least significant.)
47
DPLCommand Reference