<STX>KD
Parameter
Bit Number
Function Value(s)
w
0 - 2 BAUD Rate / Set Test Mode
0 = 9600,
1 = 600,
2 = 2400,
3 = 19200,
4 = 4800,
5 = 38400,
6 = 1200,
7 = 9600 Test Mode
3 Word Length and Parity
0 = 8 bits, no parity;
1 = 7 bits, even parity
4 - 5 Unused Set to 0
6 Always 1 Set to 1
7 Always 0 Set to 0
x
0 Print Method
0 = direct thermal,
1 = thermal transfer
1 Present Sensor
0 = not equipped,
1 = equipped
2
Control Character
[1]
0 = standard,
1 = Alternate characters
3 Cutter
0 = disabled,
1 = enabled
4
Ignore Host Distance
[2]
0 = disabled,
1 = enabled
5
Alt-2 Control Codes
[1]
0 = disabled,
1 = Alternate-2 characters
6 Always 1 Set to 1
7 Always 0 Set to 0
y
0 - 1 Sensor Type
0 = gap,
1 = reflective,
2 = continuous
2 Linerless
0 = not equipped,
1 = equipped
3 - 5 Unused Set to 0
6 Always 1 Set to 1
7 Always 0 Set to 0