vvvvi - Item Value (syntax defined later)
l
: - Item Value Delimited terminated
Configuration Upgrade Package parameters are defined in the following table.
Item
Number
Name Available
to User
(Y/N)
Value
Type
Description
1
Wireless
Upgrade Type
Y
Unsigned
short
1 - TFTP
2 - Avalanche Wavelink
3 - MSP
255 Disable
2
Configuration
File
Y String
Configuration file name
(*.cfg) for an Upgrade
Package, 256 chars max.
3
TFTP IP
address
Y String IP address of TFTP server.
4 TFTP Port Y
Unsigned
short
Port Number of TFTP Server,
default 69.
5
Upgrade
Package
Versiont
Y String
Read only.
6
Wireless
Upgrade
Beeper
Y Char
0: Off
1: On (Default)
DE DPI Emulation
This command allows printers with higher resolutions to emulate lower print
resolutions.
Parameter DE
Value / Range: 152, 200, 300, 400, 600
Units / Interpretation: Dots per inch
Command Equivalent: N/A
l
600 DPI can emulate 300 and 203 DPI resolutions.
l
400 DPI can emulate a 203 DPI resolution.
l
300 DPI can emulate a 152 DPI resolution.
82
DPLCommand Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell E-Class Series and is the answer not in the manual?

Honeywell E-Class Series Specifications

General IconGeneral
BrandHoneywell
ModelE-Class Series
CategoryPrinter
LanguageEnglish

Related product manuals