Parameter
Name
Parameter Value / Range Units / Interpretation
Command
Equivalent
Ignore Control
Codes
IC
Y, N
1, 0
Y = Enabled,
N = Disabled,
1 = Enabled,
0 = Disabled
N/A
Ignore
Distances
IE 1, 0
1 = Enabled,
0 = Disabled
N/A
Imaging Mode IL M, S
M = Multiple label,
S = Single label
N/A
Input Mode EM
0, 1, 3, 5, 7, 8,
9, 10, 11
0 = DPL,
1 = Line,
3 = PL-Z,
5 = PL-I,
7 = PL-B,
8 = PL-E,
9 = Auto,
10 = CPCL,
11 = EasyPrint
N/A
Internal
Module
IM
100 up to
max. available
(see Memory
Module
Identifiers and
Allocations).
Kbytes N/A
Label
Alignment
LA N, A, Y See LA command details. N/A
Label Rotation LR Y, N
Y = Rotate 180,
N = None
N/A
Label Store LM F, S
F = Fields,
S = States & Fields
N/A