The sample returns results from the last dot check for every element and its
resistance up to 1350 ohms [with out of range (bad or suspect) values indicates as
******], the number of dots tested, the total number of bad or suspect dots detected,
as well as the minimum, maximum, and average resistance and variance.
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
DOT OHMS
0 1148
1 1148
2 1140
.
.
.
142 1199
143 *****
144 *****
145 1050
.
.
.
830 1116
831 1116
832 1116
TOTAL BAD DOTS: 2
MIN MAX AVG VAR
921 1640 1125 719
Sample 3
<STX>KHB<CR>
The sample returns results from the last dot check for the number of elements tested,
the number of the bad or suspect dot(s), the total number of bad or suspect dots, as
well as the minimum, maximum, and average resistance and variance.
DOTCHECK RESULTS
DOTS TESTED GOOD 830 OF 832
BAD DOT LIST
143
144