The system view of the PE is displayed.
Step 2 Run:
ccc ccc-connection-name interface interface-type interface-number out-interface
interface-type interface-number
A local CCC connection is created.
----End
Postrequisite
The local CCC connection is bidirectional; therefore, only one connection is needed.
After the configurations on the PEs are complete, a local CCC connection is created.
4.3.4 Creating a Remote CCC Connection
Procedure
l Configuring the PE
Do as follows on the PEs on the two ends of the VC.
1. Run:
system-view
The system view of the PE is displayed.
2. Run:
ccc ccc-connection-name interface interface-type interface-number in-
label in-label-value out-label out-label-value { nexthop ip-address | out-
interface interface-type interface-number } [ control-word | no-control-
word ]
The remote CCC connection is created.
When you configure the PEs, specify the IP address of the next hop if the outgoing
interface is not a P2P interface (such as an Ethernet interface).
On a PE, the in-label and the out-label need to be configured for a remote CCC
connection, whereas the two static LSPs are not required. The in-label that is
exclusively used by this CCC connection serves as the static LSP.
l Configuring the P
Do as follows on the P on the VC.
1. Run:
system-view
The system view is displayed.
2. Run:
static-lsp transit lsp-name incoming-interface interface-type interface-
number in-label in-label { nexthop next-hop-address | outgoing-interface
interface-type interface-number } out-label out-label
The P is configured as a transit LSR of the static LSP.
It is unnecessary to configure static LSPs on the PEs for the CCC connection. You
should configure a bidirectional transit static LSP on all the Ps between the PEs. The
LSP transfers the data of this CCC exclusively.
Quidway S9300 Terabit Routing Switch
Configuration Guide - VPN 4 VLL Configuration
Issue 03 (2009-08-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4-9