interface GigabitEthernet/0/0
port hybrid pvid vlan 20
port hybrid tagged vlan 20
#
ccc ce1-ce2 interface Vlanif10 out-interface Vlanif20
#
interface LoopBack1
ip address 1.1.1.9 255.255.255.255
#
return
l Configuration file of CE2
#
sysname CE2
#
vlan batch 20
#
interface Vlanif 20
ip address 100.1.1.2 255.255.255.0
#
interface GigabitEthernet1/0/0
port link-type trunk
port trunk allow-pass vlan 20
#
return
4.11.2 Example for Configuring a Remote CCC Connection
Networking Requirements
The CE is connected to the PE through a GE interface.
To create a remote CCC connection between CE1 and CE2, you need to complete the following
tasks:
l Create the remote CCC connection between the two PEs.
l Configure two static LSPs on P to exchange packets.
4 VLL Configuration
Quidway S9300 Terabit Routing Switch
Configuration Guide - VPN
4-40 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 03 (2009-08-20)