EasyManua.ls Logo

KAESER ESD.2C - Checking the Coupling; Motor Running

KAESER ESD.2C
413 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The required quantity of grease is stated on the motor nameplate.
Precondition Motor running
1. Clean the nipple 1 with a cloth before greasing.
2. Grease both bearings with a grease gun.
3. Reset the maintenance interval counter.
Fan motor:
Nipples for re-greasing the motor bearings are located on the outside of the machine.
The lines to the bearings are pre-filled with bearing grease.
The required quantity of grease is stated on the motor nameplate.
Precondition Motor running
1. Clean the nipple 2 with a cloth before greasing.
2. Grease both bearings with a grease gun.
3. Reset the maintenance interval counter.
Fan motor:
Have the fan motor bearings checked by a KAESER Service Technician during the regular
maintenance calls.
10.10 Checking the Coupling
A defective coupling is recognisable by:
noisy running,
surface cracks,
colour change.
WARNING
Danger of injury from rotating coupling!
Never switch the machine on without the safety screen in place over the coupling.
10 Maintenance
10.10 Checking the Coupling
ESD_2C_10357405_10–LIN_00 E
Service Manual Screw Compressor
ESD 442/14 bar (abs) SFC SIGMA CONTROL 2
63
Option K1
Option K2/K9

Table of Contents