4. Press «Enter» to save the setting.
The «IDLE» key is deactivated.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.2.3 Load control
Menu
pA/pB DO DOR1.04 ☐
·········
Load RC DI1.13 ok ☑
loc.-load RC DI1.09 ☑
·········
Key idle : ☐
Active line with deactivated check box
5. Press «Esc» repeatedly to return to the Main Menu.
Result Thus, it is ensured that unauthorized users can press the «IDLE» key without the machine switch‐
ing to IDLE.
7.5 Configuring machine start and stop
➤ In addition to manually starting the machine locally, you have the following alternatives:
Function State on delivery, setting See
Automatic start/stop in programmed clock mode No clock (time) program entered 7.5.1
Holidays Not set 7.5.2
Remote start, e.g. from a control centre. Deactivated 7.5.3
IDLE (venting) Activated 7.5.4
Automatic restart after power failure (after delay period). Activated 7.5.5
Tab. 57 Settings for machine start and stop.
7.5.1 Automatic start/stop in programmed clock mode
Overview
■ If not activated, enter password for level 2
■ Select the <Compressor clock> menu
■ Set/adjust the time program
■ Activate the «Clock» key
7.5.1.1 Selecting the compressor clock menu
Precondition Password level 2 is activated.
The display shows the operating mode.
1. Press «Enter».
The main menu is displayed.
7 Initial Start-up
7.5 Configuring machine start and stop
9_9450 03USE
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
65