Examples of unsuitable fixing points:
Pipe sockets
Flanges
Attached components such as cyclone separators, condensate drains or filters
Rain protection covers
Please consult with KAESER if you have questions to the appropriate lifting gear.
Precondition The lifting gear complies with local safety regulations.
No pressure should bear on the sides of the machine cabinet.
Fig. 39 Transport with a crane
1 Lifting gear
2 Slings
1.
NOTICE!
The machine can be damaged by incorrect attachment of the lifting gear!
Do not attach the lifting gear to any of the machine components.
2. Use the lifting gear correctly and lift the machine carefully.
12.5 Disposal
When disposing of a machine, drain out all liquids and remove old filters.
Precondition The machine is decommissioned.
1. Completely drain the cooling oil from the machine.
2. Remove used ail filter and separator cartridge.
3. Hand the machine over to an authorised disposal expert.
Components contaminated with cooling oil must be disposed of in accordance with local
environment protection regulations.