3. Press «Enter» to switch into setting mode.
n.a.
flashes in the active line.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.2.3.1 pA/pB Clock
Menu
·········
01 Mon-Fri 06:30 pA
Active line (settings for weekdays, time, pA)
02 Mon-Fri 12:00 pB
(Settings for weekdays, time, pB)
03 Mon-Fri 13:00 pA
04 Mon-Thu 17:00 pB
05 Fri 16:00 pB
4. Use «DOWN» or «UP» to set the weekdays and confirm by pressing «Enter».
5. Press the «Right» key once.
6. Press «Enter» once.
The column time, display for hours,
00: 00
in the active line flashes.
7. Use «UP» or «DOWN» to change the hour setting.
8. Press the «Right» key once.
9. Column, minutes display,
00
00
flashes in the active line.
10. Use «DOWN» or «UP» to set the time (minutes) and confirm by pressing «Enter».
The display stops flashing and the time (hours/minutes) is set.
11. Press the «Right» key once.
12. Press «Enter».
The display for the system setpoint pressure pA/pB flashes.
13. Use «UP» or «DOWN» to change the setting for pA or pB.
14. Specify further switching points in the same manner.
Deleting the existing clock program
Take the following steps to delete an existing clock program:
Precondition Password level 2 is activated.
The
< Configuration ➙ Pressure settings ➙ Load control >
menu is selected.
1. Press «DOWN» repeatedly until
pA/pB Clock
is displayed as the active line.
2. Press «Enter».
The current clock program is displayed.
3. Press the «UP» repeatedly until
Reset
is displayed as the active line.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.2.3.1 pA/pB Clock
Menu
Reset: ☐
Active line
·········
01 Mon-Fri 06:30 pA
02 Mon-Fri 12:00 pB
03 Mon-Fri 13:00 pA
04 Mon-Thu 17:00 pB
7 Initial Start-up
7.8 Configuring the machine for local mode
84
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3 9_9450 03USE