After switching on the power supply, the bus alarm can be suppressed temporarily.
■ Settings for SIGMA AIR MANAGER without SIGMA AIR CONTROL PLUS
─ Start: 30 seconds
■ Settings for SIGMA AIR MANAGER with SIGMA AIR CONTROL PLUS
─ Start: 40 seconds
1. Press «DOWN» five times.
The
Start
line is displayed as the active line.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
8.2 Com-Module
Menu
Reset: ☐
Slave No. : 102
·········
Bus alarm
Start td : 30 s
Active line
Timeout : 5 s ☑
2. Press «Enter» to switch into setting mode.
3. Use «UP» or «DOWN» to adjust the setting.
4. Press «Enter» to accept the setting.
Activate the communications module
1. Press «UP» five times.
The
Com-Module Start
line is displayed as the active line.
2. Press «Enter» to switch into setting mode.
The
check box
flashes.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
8.2 Com-Module
Menu
Status Counter 0
Com module not recognised
·········
Type None
Com-Module Start : ☐
Active line
Reset: ☐
3. Press «UP».
7 Initial Start-up
7.9 Configuring the machine for master control
9_9450 03USE
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
95