Fig. 18 Switching on and off from a remote control centre
1 «Remote control» key
2
Remote control
LED
1. Attach an easily seen notice to the machine that warns of remote operation.
Remote control: danger of unexpected starting!
Make sure the power supply disconnecting device is switched off before commencing any
work on the machine.
Tab. 33 Machine identification
2. Label the starting device in the remote control centre as follows:
Remote control: danger of unexpected starting!
Before starting, make sure that no one is working on the machine and that it can be safely
started.
Tab. 34 Remote control identification
3. Press the «remote control» key.
The
remote control
LED lights. The machine can be remotely controlled.
8.4 Switching on and off with the clock
Precondition The clock is programmed.
8 Operation
8.4 Switching on and off with the clock
50