4. Press «Enter» to switch into setting mode.
Key
flashes.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.4.1 Compressor on
Menu
Local mode : Key
Remote mode : Key
Active line
·········
current Key
·········
RC DI 1.12 ok ☑
5. Press «DOWN» repeatedly until
Key+RC
is displayed.
6. Press «Enter» to accept the setting.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.4.1 Compressor on
Menu
Local mode : Key
Remote mode : Key+RC
Active line
·········
current Key
·········
RC DI 1.12 ok ☑
Result The machine start is set to remote operation with
Key+RC
.
7.5.3.2 Activating/deactivating the «Remote control» key
Precondition The electrical connection has been made.
Password level 2 is activated.
The display shows the operating mode.
1. Press «Enter».
The main menu is displayed.
2. Select the
< Configuration ➙ Compressor start ➙ Compressor on >
menu.
3. Press «DOWN» repeatedly until
Key remote
is displayed as active line.
4. Press «Enter» to switch into setting mode.
The
check box
for the remote control key will flash.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
5.4.1 Compressor on
Menu
Local mode : Key
Remote mode : Key+RC
·········
RC DI 1.12 ok ☑
Key remote : ☐
Active line with check box
Key clock : ☐
7 Initial Start-up
7.5 Configuring machine start and stop
70
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3 9_9450 03USE

Table of Contents