2. Select the
< Communication ➙ Com-Module >
menu.
The
< Com-Module >
menu is displayed.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
8.2 Com-Module
Menu
Status Counter 0
Active line
Com module not recognised
·········
Type None
Com-Module Start : ☐
Reset: ☐
3. Press «DOWN» six times.
The
Slave
line is displayed as the active line.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
8.2 Com-Module
Menu
Type Profibus
Detected communication module
Com-Module Start : ☐
Reset: ☐
Slave No. : 103
Active line
·········
Bus alarm
4. Press «Enter» to switch into setting mode.
The
Slave
display flashes.
5. Press «DOWN» once.
6. Press «Enter» to accept the setting.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
8.2 Com-Module
Menu
Type Profibus
Detected communication module
Com-Module Start : ☐
Reset: ☐
Slave No. : 102
Active line
·········
Bus alarm
Result Slave address 102 is set.
Setting the reaction for a bus fault
Exchange of data with a Profibus connection takes place in fixed cycles. The Profibus connection
can be monitored with the help of the cycle time:
The bus connection is considered to be interrupted if no data is exchanged between the bus mas‐
ter and the controller (as bus subscriber) after the expiry of a set time period (time-out).
Time-out monitoring is activated. You may neither adjust nor deactivate time-out for
SIGMA AIR MANAGER.
7 Initial Start-up
7.9 Configuring the machine for master control
94
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3 9_9450 03USE