Feature Value
Current consumption IOM 3 [A] 1,6
IOM ≙ input/output module
Tab. 17 Power supply specifications
2.1.2.2 Maximum cable lengths
Input/Output Conductor length [ft]
Analog input current (AII),
Analog input resistor (AIR)
Analog output current (AOI)
100
Digital input (DI),
Digital output relay (DOR)
330
Digital output resistor (DOT) 100
Tab. 18 Cable lengths
2.1.2.3 Input/output modules – degree of protection
Feature Value
Degree of protection within the machine IP 54
Degree of protection within the control cabinet IP 20
Tab. 19 Degree of protection, IOM
2.1.2.4 Input/output modules – dimensions
Feature Value
Width [in] 4.9
Height [in] 9.8
Depth [in] 1.7
Tab. 20 IOM dimensions
2.1.3 Sensors
Pressure transducer
Feature Value
Output signal [mA] 0/4–20
Connection Twin cable
Tab. 21 Pressure transducer
Resistance thermometer
Feature Value
Sensing resistance (to DIN IEC 751) PT100
2 Technical Data