8.8 Displaying operating data
The following information can be called up in the
<Operating data>
menu option:
<Operating hours>
Compressor: Total machine running time
Load run: Machine running time in LOAD mode
Compressor motor: Running time of compressor motor (adjustable)
Airend: Running time of airend (adjustable)
SIGMA CONTROL 2 : Controller running time
Displaying operating data
Precondition Access level 2 is activated.
1. In operating mode, switch to the main menu with the «Enter» key.
2. Select
< Operating data >
.
The
Operating data
menu is displayed.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
3 Operating data
Menu
▶1 Operating hours
Active line
▶2 kWh counter
·········
Load valve on 383
Total number of switching actions
Changing the operating hours
The running times of the compressor motor and the airend can be adjusted. This may be required
after a replacement, for example.
Precondition Access level 2 is activated.
1. Select the
< Operating data ➙ Operating hours >
menu.
The
Operating hours
menu is displayed.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
3.1 Operating hours
Menu
Compressor 3050 h
Active line
On load 3030 h
Motor 3050 h
Compressor block 3050 h
SIGMA CONTROL 2 3050 h
2. Press «DOWN» repeatedly until
Compressor block
is displayed as the active line.
8 Operation
8.8 Displaying operating data
148
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3 9_9450 03USE

Table of Contents