3. Press «Enter» to accept the setting.
The offset is reset to
32 °F
.
The test mode is deactivated and the test is completed.
4. Press «Escape» repeatedly to return to the main menu.
Resetting
SIGMA CONTROL 2 will display the highest measured value if the test for switching off at overtem‐
perature is aborted.
Activate the check box for reset in order to reset the stored value.
➤ Activate the check box.
8 Operation
8.11 Checking the temperature sensor and overheating shutdown function
156
Service manual Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3 9_9450 03USE