EasyManua.ls Logo

KAESER ESD.2C - Page 409

KAESER ESD.2C
413 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Helium unit
Measurement record
for helium screw compressor units
Compressor unit Type/Serial-No.:
ESD 442 SFC 14,0 bar(a) HE a.c. /480V 60Hz / 1205 - Linde CH, Proj. Florence12, USA
Mat.No.:
ESD.2C
Equipment-No.:
4824071
Airend Type/Serial-No.:
Sigma 38 Helium / 1014 EQ.-No. 788085
Motor Type/Serial-No.: Make:
Siemens
Rated power [kW]:
250
Speed [min
-1
]:
Warranty terms
Suction temperature T
A
:
298
K
Suction pressure p
A
:
1,05
bar (abs) Rate of mass flow m:
31,1
g/s
Tol.:
+5 / -2
%
Unit outlet pressure p
e
:
14,0
bar (abs)
Power input P
IN
:
111,6
kW
Tol.:
+/- 3
%
Measurement results
Ambient pressure p
U
:
0,984
bar (abs)
Ambient temperature T
U
:
298
K
Suction temperature T
A
:
299,6
K
Discharge temp. T
(END)
:
327
K
Unit outlet temperature T
(OUT)
:
---
K
Gas meter inlet temperature T
B1
:
299,1
K
Gas meter outlet temp. T
B2
:
---
K
Suction pressure p
A
:
1,05
bar (abs)
Unit outlet pressure p
e
:
14,0
bar (abs)
Gas meter working pressure p
B
:
5,74
bar (abs)
Gas meter working volume V
B
:
10,0
Duration of measurement t:
5,18
min
Compressor speed n
K
:
595
min
-1
Deviation
Package power input P
IN
:
108,2
kW
20 Hz
-3,05
%
Pressure ratio:
5,74
5,467
1,05
Free gas delivery (referring to inlet conditions ) [m³/min]
10,0 299,60
5,467
10,571
5,18 299,10
Density at inlet conditions [kg/m³]
273,15 1,05
0,1785
0,1687
299,60 1,013
Rate of mass flow [g/s]
10,571 0,1687
29,72
Remarks: Deviation
For T
A
=
298,0 K and res. ρA = 0,1696 mass flow will result in approx. m = 29,88 g/s
-3,93
%
Date: Name:
M. Skrobek
1LG6318-4AA96-Z
30.08.13
V
A
=
t
=
V
B
T
B
T
A
Z
x x
=
x x
=x x
ρ
A
=
=
p
N
p
A
x x
ρ
N
T
A
T
N
=
x
m =
=
x
x
60
1000
V
A
ρ
A
x
60
1000
Z =
p
A
p
B
=
=

Table of Contents